http://www.wi-inf.uni-essen.de/~schwarze/nt/karten/scsi11.html (Einblicke ins Internet, 10/1995)
BusLogic BT-542D
BusLogic BT-542D
This is the BusLogic 542D SCSI adapter shown. Listed below are the possible Interrupt Request Line (IRQ), Base I/O
Address, Base Memory Address, and other jumper/switch configurations:
Setup Choice for Windows NT 3.5
BusLogic Family
Type of External SCSI Connector
Low Density Shielded
SWITCH BAY 1
SCSI
ID SW1 SW2 SW3
0 OFF OFF OFF
1 ON OFF OFF
2 OFF ON OFF
3 ON ON OFF
4 OFF OFF ON
5 ON OFF ON
6 OFF ON ON
7 ON ON ON
SW4
SCSI PARITY ENABLE/DISABLE
SW5
DISK > 1GB and not SCO UNIX ENABLE/DISABLE
SW6
SCSI SYNCHRONIZATION NEGOTIATION ENABLE/DISABLE
DMA
CHANNEL SW7 SW8
Disable OFF OFF
5 ON ON
6 OFF ON
7 ON OFF
SWITCH BAY 2
I/O
ADDRESS SW1 SW2 SW3
Reserved OFF OFF OFF
134H-137H ON OFF OFF
234H-237H OFF ON OFF
334H-337H ON ON OFF
Reserved OFF OFF ON
130H-133H ON OFF ON
230H-233H OFF ON ON
330H-333H ON ON ON
AT
IRQ SW6 SW7 SW8
Reserved OFF OFF OFF
Reserved ON OFF OFF
15 OFF ON OFF
14 ON ON OFF
12 OFF OFF ON
9 ON OFF ON
10 OFF ON ON
11 ON ON ON
SWITCH BAY 3
BIOS
ADDRESS SW3 SW4 SW5
Disable OFF OFF OFF
Reserved ON OFF OFF
0C8000H OFF ON OFF
0CC000H ON ON OFF
0D0000H OFF OFF ON
0D4000H ON OFF ON
0D8000H OFF ON ON
0DC000H ON ON ON
MAXIMUM SYNCHRONOUS
DATA RATE SW6
10.0 MB/SEC. OFF
5 MB/SEC. ON
SW7
Reserved
SW8
Reserved
HOST BUS
TRANSFER RATE SW1 SW2
8.0 MB/SEC. OFF OFF
6.7 MB/SEC. ON OFF
5.7 MB/SEC. OFF ON
5.0 MB/SEC. ON ON
JUMPER SETTINGS
HOST
IRQ W3 W4 W5 W6 W7 W8
9 OFF OFF OFF OFF OFF ON
10 OFF OFF OFF OFF ON OFF
11 OFF OFF OFF ON OFF OFF
12 OFF OFF ON OFF OFF OFF
14 OFF ON OFF OFF OFF OFF
15 ON OFF OFF OFF OFF OFF
W17
HOST I/O CNANNEL READY ENABLE/DISABLE
FLOPPY I/O
ADDRESS W14
PRIMARY (3FX) OFF
SECONDARY (37X) ON
FLOPPY
CONTROLLER W15 W16
DISABLE OFF OFF
ENABLE ON ON
Zurück zur Übersicht